Choose language 中文 English

    Combined Type Air Dryer

    Brief introduction:

    Inlet air temperature 20-45

    The inlet pressure 0.6-1.0MPa

    The pressure loss is less than or equal to the inlet pressure of 5%

    Pressure dew point standard -40 C

    Regeneration gas consumption 3%-5%

    Cooling water

    The environmental temperature are less than 32

    * combination dryer 80 cubic meters and above for no split box board bare metal

    * special requirement can acceptable.


    Description

    Model Specification

    Optional Accessories

    Feedback


     

         

    The performer, Pitzer refrigeration compressor or the same grade, To ensure the long-term, reliable performance, stable operation of equipment.



    The evaporator adopts copper tube expansion sleeve structure of aluminum fin, High heat transfer efficiency, dew point protection.

     

     

    Using Danfoss or the same level dry filter products, Small size, large filter area, can effectively filter the frozen In the system of water and impurities, improve system cleanliness, To reduce the failure rate of equipment.

     

    Using Danfoss or the same level of thermal expansion valve, can rely on the stem Dry machine load size automatically adjust the number of supply of refrigerant, from And the purpose of saving energy

     

     

     

    Water condenser tube structure with high efficiency, high heat efficiency, ensure the normal, stable operation.


     

     

    The pressure controller uses Danfoss or the same grade products, ensure the accuracy of control equipment

    High temperature and high humidity from the compressor to the compressed air, the first in the heat exchanger and dried at low temperature heat exchange of compressed air, reduce the temperature, then enters into the evaporator is further cooled to 2 C So, this pressure dew point water has become the most gaseous liquid water is discharged, then low temperature drying compressed air into the heat exchanger, cooling air temperature and humidity, and temperature also increased, to prevent the external condensation conveying pipeline, the humidity is low compressed air into the adsorption tube is further drying dehumidification, get lower dew point of product gas.

     





    Model   

    Flow capacity
     (Nm3/min)

    Desiccant
     (kg)

    Air

    Connection diameter

    Cooling water connection end

    Refrigeration power
     (HP)

    Cooling water supply
     (Nm3/h)

    Voltage

    (V)

    Weight
     (kg)

    Length

    (mm)

    Width

    (mm)

    Height

    (mm)

    SDZW-6

    6.8

    112

    G1 1/2"

    R1"

    2

    1.2

    220

    760

    1500

    1160

    1940

    SDZW-8

    8.5

    156

    G2"

    R1"

    2.5

    1.6

    220

    960

    1500

    1100

    2116

    SDZW-10

    10.9

    197

    G2"

    R1"

    3

    1.8

    380

    1120

    1500

    1240

    2316

    SDZW-12

    12.8

    220

    G2"

    R1"

    3

    2

    380

    1190

    1500

    1240

    2316

    SDZW-15

    16

    273

    DN65

    R1 1/2"

    4

    3

    380

    1660

    1800

    1450

    2192

    SDZW-20

    22

    395

    DN65

    R1 1/2"

    5

    3.6

    380

    1740

    1970

    1610

    2470

    SDZW-25

    26.8

    491

    DN80

    R1 1/2"

    6

    4.6

    380

    2075

    2030

    1630

    2505

    SDZW-30

    32

    600

    DN80

    R1 1/2"

    7

    5.6

    380

    2200

    2240

    1840

    2519

    SDZW-40

    43.5

    722

    DN100

    R1 1/2"

    10

    7.2

    380

    2848

    2360

    1900

    2637

    SDZW-50

    53

    862

    DN100

    R1 1/2"

    12

    9.2

    380

    3144

    2600

    2000

    2638

    SDZW-60

    67

    1030

    DN125

    R1 1/2"

    13.3

    10.8

    380

    3361

    2540

    2100

    2719

    SDZW-80

    90

    1333

    DN125

    R1 1/2"

    20

    12.4

    380

    4500

    2640

    2500

    2818

    SDZW-100

    110

    1940

    DN150

    R2"

    25

    14.6

    380

    6550

    2960

    2670

    2985

    SDZW-120

    130

    2370

    DN150

    R2"

    25

    16.2

    380

    7810

    3070

    2800

    3041

    SDZW-150

    160

    2785

    DN200

    R2 1/2"

    40

    18.6

    380

    8500

    3600

    3130

    3190

    SDZW-200

    210

    3374

    DN200

    R2 1/2"

    60

    24.4

    380

    9600

    3700

    3450

    3311

    SDZW-250

    260

    4580

    DN250

    R3"

    70

    30.5

    380

    12100

    4230

    4110

    3569

    SDZW-300

    315

    5354

    DN250

    R3"

    80

    36

    380

    12800

    4700

    4210

    3730


    •  The dew point temperature

    •  Pressure dew point meter

    •  Special voltage

    •  Water regulating valve

    •  This is not limited to