Choose language 中文 English

    SCLF Series Air-cooled Box Type Chiller(7 ℃/-5℃)

    Brief introduction:

    General Instruction:

    1 Using the scroll compressor or piston compressor like Hitachi,Sanyo,Performer or Bitzer

    2 Adopting refrigeration components like Emerson

    3 electrical control components Danfoss,Sporlan

    4 Basic installation, simple operation.


    Description

    Model Specification

    Optional Accessories

    Feedback



    Using screw Hanbell, Fu Sheng or the same grade Refrigeration Compressor,To ensurereliable performance, Preparation of long-term, Stable operation.


     

    The Jin Teng or the same level dry filter products, Small volume,Large filter area, dry filter The core is using Emerson or The same level of the products to have Effect of water and refrigeration systemThe impurities,provided High cleanliness of the system, reduce the failure rate of equipment.


     

     

     

    The dry evaporator shell and tube type structure, heat transfer EfficientCompact 

    structure, small occupied area,. Program; high temperature resistance ,High pressre, guarantee system Often, stable operation;maintenance FeeLow, Yi Cao For.


     


    The wind condenser copper tube expanding sleeve structure of aluminum fin, Heat transfer Efficient Air flow rate, increase the system The Radiation effect,Ensure the normal,Stable operation.


      

    Using Danfoss or the same level of thermal expansion valve, can rely onThe dryer load The size of the automatic adjust the number of refrigerant supply,In order to save energy Objective.

     

    The unit is equipped with pressure protection, motor protection, frost protection,Safety valve Compressor protection, overheat protection of motor protection Device, ensure that the unit. Stable operation


     

    Low temperature refrigerant gas is sucked into the compressor, compressed by compressor, arefrigerant gas, high temperature and high pressure into the condenser, heat exchange with the outside environment, so as to condense into liquid refrigerant, liquid refrigerant through the drying filter and then through thermal expansion valve, pressure reducing refrigerant into the evaporator, and evaporation into a low pressure gaseous refrigerant, the refrigerant gas before entering the compressor, so move in circles, so as to achieve the cooling effect.

     

    Item

    Model

    SCLF-3-C-X

    SCLF-5-C-X

    SCLF-7-C-X

    SCLF-10-C-X

    SCLF-12-C-X

    SCLF-15-C-X

    SCLF-20-C-X

    SCLF-25-C-X

    SCLF-30-C--S-X

    SCLF-40-C-S-X

    refrigerating capacity

    KW

    7.55

    12.45

    18.5

    28.4

    33

    41.6

    57

    70.8

    83.2

    114

    ×103KCal/hr

    6.5

    10.7

    15.9

    24.4

    28.4

    35.8

    49.0

    60.9

    71.5

    98.0

    Compressor

    Quantity(PC)

    1

    1

    1

    1

    1

    1

    1

    1

    2

    2

    Cooling input power

    2.3

    3.6

    5

    7.2

    8.3

    11.2

    15.5

    21.4

    22.4

    31

    machine power

    KW

    2.9

    4.5

    6.4

    8.9

    10.7

    13.6

    18.3

    24.7

    25.7

    35.3

    condenser

    Type

    Efficient copper tube and  aluminum foil tightly Expansion fin heat ex-changers

    Fan

    Input power

    0.2

    0.3

    0.6

    0.9

    0.9

    0.9

    1.4

    1.8

    1.8

    2.7

    evaporator

    Type

    Shell and tube dry type high efficient  heat ex-changers

    Frozen water

    flow capacity

    1.3

    2.1

    3.2

    4.9

    5.7

    7.2

    9.8

    12.2

    14.3

    19.6

    Water-pipe joint

    DN25

    DN40

    DN50

    DN65

    Safety protection device

    Refrigerant high and low voltage protection, over-current protection,  frost protection, electronic delay protection, etc.

    Power

    Three-phase four-wire power  supply

    Size

    Length(mm)

    940

    960

    1300

    1460

    1560

    1700

    1950

    2100

    2200

    2450

    Width (mm)

    750

    750

    850

    850

    850

    1000

    1150

    1250

    1250

    1350

    Height(mm)

    1330

    1370

    1530

    1530

    1430

    1620

    1790

    1610

    1880

    1960

    Weight

    KG

    140

    210

    300

    360

    450

    650

    750

    1050

    1250

    1350

    Description

    1.The above-mentioned table working condition ofrefrigeration: Cold water inlet temperature 12℃,Cold water outlet temperature 7℃,ambient temperature 35℃。

    2.The machine’s safe operating range: chilled waterinlet temperature 9-20℃.

    3.This series unit uses fully enclosed compressorimported from Europe and theUnited  States, superior performance, stronganti-strike liquid capability :

    4.Power supply: three-phase four-wire system  380V/220V 50HZ

    5.Refrigerating medium: R22


    • Compressor

    • Pressure dew point meter

    • Special voltage

    • Condenser fan

    • This is not limited to